Constant Watt Heating Cable
Category: Self-regulating & Constant watt heating cable  Publish Time: 2012-09-23 16:22 
Parallel constant wattage heating cable   Parallel constant wattage heating&nb
Constant Watt Heating Cable

Parallel constant wattage heating cable

 

Parallel constant wattage heating cable can be used for pipe and equipment freeze protection and process temperature maintenance requiring high power output or high temperature exposure. This type provide an economical alternative to self regulating heating cable but requires more skill for installation and more advanced control and monitor system.Constant wattage heating cables can provide process temperature maintenance up to 150°C and can withstand exposure temperatures up to 205°C with power on.

 

Working principle

Two paralleled stranded copper wire as the bus wires with insulation layer FEP,then wrap the nickel-chromium alloy as the heating wire connect with bus wires at regular intervals,form the parallel resistance.finally covered with insulation jacket FEP.When the bus wires power on,each parallel resistance begin to heat.thus form a continuous heating cable.

 

Structure

 

1.Tinned copper stranded wire       2.FEP insulation layer

3.FEP insulation layer              4.Ni-Cr alloy wire

5.PEP insulation layer             6.Tinned copper Metal braid            7.FEP outer sheath

 

RDP2 Single phase constant wattage heating cable used to freeze protection,heat preservation for all kinds of pipelines and instruments.Application such as factory Zone 1,Zone 2 explosive gas atmosphere area. 

 

Rated voltage:230V            Max exposure temperature:200°c

Normality insulation resistance:20M ohm        Protection level:IP54

Dielectric strength:2000V 50Hz/1min           

Insulation material:FEP                       Size:6.3×9.5mm

 

RDP3 Three phase constant wattage heating cable

 

Three phase constant wattage heating cable adopt three phase triangle power supply.have the characteristics of single phase constant power heating cable.special used for long distance and large diameter pipelines heat tracing and preservation.Application such as factory Zone 1,Zone 2 explosive gas mixture T3 area. 

 

Structure

 

 

2.Tinned copper stranded wire       2.FEP insulation layer

4.FEP insulation layer              4.Ni-Cr alloy wire

5.PEP insulation layer              6.Metal braid            7.FEP outer sheath

 

Working principle

Three paralleled stranded copper wire as the bus wires with insulation layer FEP,then wrap the nickel-chromium alloy as the heating wire connect with bus wires at regular intervals,repeated cycle connection (like:AB-BC-CA-AB)form the parallel resistance between two phase.finally covered with insulation jacket FEP.When the bus wires power on three phase,each parallel resistance begin to heat.thus form a continuous heating cable.

 

 

 

Rated voltage:.380V                          Max exposure temperature:200°c

Normality insulation resistance:20M ohm        Protection level:IP54

Dielectric strength:2500V 50Hz/1min                   

Insulation material:FEP                       Size:6.3×12mm

 

Series constant wattage heating cable

 

RDCHR series connection constant wattage heating cable use the core conductor as the heating element,when the core conductor connect to power supply,the core conductor will send out joule heat,because unit length constant power heating cable 's current and resistance is equal to all length heating cable.so the heating value of each unit is equally.not result in the power of terminal end is lower than beginning end with the increasing length of heating cable.so this type is suitable for long pipeline and large diameter pipelines heat tracing and heat preservation.power supply by one power point.

 

A.Conductor core                   B.C.D.FEP insulation layer and outer sheath

E.Metal braid                      F.FEP Strengthen sheath 

 

specification and technical features

Rated voltage:110V-120V.220V-380V,660V,1100V

Insulation resistance:750MKm

Dielectric strength:2×nominal voltage + 2500V

Max withstand temperature:J3-205 centigrade degree,J6-250 centigrade degree

Min installation temperature:50 centigrade degree

 

 

Prev product:No prev product
Next productSelf Regulating Heating Cables